Delta UPS - Ultron Family
The power behind competitiveness
www.deltapowersolutions.com
HPH Integrated Battery Series, Three Phase
20/30/40 kVA
User Manual
N
O
RM
A
L
B
A
TTE
RY
B
YP
A
S
S
F
A
U
L
T
ON
OFF
ESC

Questions and Answers

  • C
    Calvin WrightAug 7, 2025
    What to do if my Delta UPS is overloaded?
    • R
      rcooleyAug 8, 2025
      If your Delta UPS is overloaded, it means the current load exceeds its capacity. To resolve this, remove some unnecessary devices to ensure the total load capacity is below 95%.
  • M
    Mary KnightAug 13, 2025
    How to fix OVER TEMPERATURE on Delta Ultron GES403HH33A035?
    • H
      Heather PowersAug 13, 2025
      If your Delta UPS displays an 'OVER TEMPERATURE' warning, it means the internal temperature is too high. Try the following: * Ensure the UPS is in a well-ventilated area. * Reduce the number of connected devices to decrease the load. * Check if the fans are functioning correctly.
  • C
    Charles WalkerAug 17, 2025
    What to do if Delta Ultron GES403HH33A035 UPS shows PFC AMBIENT OVER TEMP. FAIL?
    • K
      karen72Aug 18, 2025
      If your Delta UPS shows a 'PFC AMBIENT OVER TEMP. FAIL' error, the UPS temperature is too high. You can: 1. Move the UPS to a well-ventilated location. 2. Decrease the amount of connected loads. 3. Verify that the fans are running normally.
  • S
    stephaniedavisAug 22, 2025
    What to do if Delta UPS shows BATTERY LOW SHUTDOWN?
    • D
      Dana ChanAug 22, 2025
      If the Delta UPS displays 'BATTERY LOW SHUTDOWN', it indicates that the battery voltage is low. To resolve this, charge the batteries.
  • D
    Danielle RossAug 27, 2025
    What to do if Delta UPS shows DC BUS HIGH SHUTDOWN?
    • L
      Luis ColemanAug 27, 2025
      If your Delta UPS displays a 'DC BUS HIGH SHUTDOWN' error, this indicates that there may be abnormalities with the output or internal faults within the UPS. In this case, contact service personnel for assistance.
  • C
    Caroline HouseSep 1, 2025
    What to do if Delta Ultron GES403HH33A035 UPS shows DC BUS LOW SHUTDOWN?
    • M
      Melissa LaneSep 1, 2025
      If your Delta UPS displays a 'DC BUS LOW SHUTDOWN' error, this indicates that there may be abnormalities with the output or internal faults within the UPS. In this case, contact service personnel for assistance.

Summary

Chapter 1: Important Safety Instructions

1.1 Placement Warnings

Guidelines for safely installing the UPS to ensure proper ventilation.

1.2 Connection Warnings

Critical warnings regarding proper grounding and protective devices for UPS connections.

1.3 Usage Warnings

Essential precautions for operating the UPS, including load types and environment.

Chapter 4: Operation Modes

Online Mode

Explanation of the UPS's operation when supplying power via the inverter.

ECO Mode

Details on the ECO mode for enhanced energy efficiency and its operating conditions.

Battery Mode

How the UPS operates when running on battery power during an outage.

Chapter 6: Installation and Wiring

6.1 Precautions Prior to Installation and Wiring

Essential safety precautions and recommendations before starting installation.

6.2 Installation Environment

Guidelines for selecting an appropriate installation location for the UPS.

6.4 UPS Installation

Procedures for installing the UPS, including using levelers and balance supports.

6.5 Wiring

General guidance and precautions for wiring the UPS system.

6.5.1 Precautions Prior to Wiring

Specific safety warnings and requirements before performing any electrical wiring.

6.5.2 Single Input; Dual Input Modification

Steps to modify the UPS configuration from single input to dual input.

6.6 External Battery Cabinet Connection Precautions

Important safety guidelines for connecting external battery cabinets.

Chapter 7: Operation

Chapter 10: Maintenance

Chapter 11: Troubleshooting

Short Circuit Troubleshooting

Solutions for UPS issues related to short circuits.

Inverter Fail Troubleshooting

Troubleshooting steps for inverter failure alarms.

Over Temperature Troubleshooting

Resolving UPS issues caused by excessive temperature.

Appendix 1: Technical Specifications

Appendix 2: Warranty

Delta Ultron GES403HH33A035 Specifications

General IconGeneral
BrandDelta
ModelUltron GES403HH33A035
CategoryUPS
LanguageEnglish