Chapter 4 Parameters
VFD-EL-W
4-99
01.09 Accel. Time 1 0.1–600.0 / 0.01–600.00 sec. 10.0 0.5 0.5 Adjusts according
to customer’s
applications
01.10 Decel. Time 1 0.1–600.0 / 0.01–600.00 sec.
10.0 5.0 5.0
01.12 Decel. Time 2 0.1–600.0 / 0.01–600.00 sec. 10.0 3.0 3.0
The time the AC
motor drive
decelerates to
stop when the
pressure reaches
the setting value.
Parameter
Function Settings Default
End
user’s
master
End
user’s
slave
Note
02.00
First Master
Frequency
Command Source
0: Digital keypad UP/DOWN
keys or Multi-function Inputs
UP/DOWN.
1: 0–10 V from AVI
2: 4–20 mA from ACI
3: RS-485 (RJ45)
communication
4: Digital keypad potentiometer
0 2 2
Adjusts according
to customer’s
applications
02.01
First Operation
Command Source
0: Digital keypad
0 0 0
Adjusts according
to customer’s
applications
1: External terminals. Keypad
STOP/RESET enabled.
2: External terminals. Keypad
STOP/RESET disabled.
3: RS-485 communication.
Keypad STOP/RESET
enabled.
4: RS-485 communication.
Keypad STOP/RESET
disabled.

Table of Contents

Other manuals for Delta VFD-EL-W Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD-EL-W Series and is the answer not in the manual?

Delta VFD-EL-W Series Specifications

General IconGeneral
BrandDelta
ModelVFD-EL-W Series
CategoryDC Drives
LanguageEnglish

Related product manuals