Chapter 11 Summary of Parameter SettingsMS300
227
Pr.
Explanation
Settings
Default
03-65
AVI Voltage Mid-Point
0.00–10.00 V
5.00
03-66
AVI Proportional Mid-
Point
-100.00–100.00%
50.00
03-67
AVI Voltage Highest Point
0.00–10.00 V
10.00
03-68
AVI Proportional Highest
Point
-100.00–100.00%
100.00
03-69
Negative AVI Voltage
Lowest Point
-10.00–0.00 V
(valid when Pr.03-28 sets as -1010 V)
0.00
03-70
Negative AVI Proportional
Lowest Point
-100.00–100.00%
(valid when Pr.03-28 sets as -1010 V)
0.00
03-71
Negative AVI Voltage
Mid-Point
-10.00–0.00 V
(valid when Pr.03-28 sets as -1010 V)
-5.00
03-72
Negative AVI Proportional
Mid-Point
-100.00–100.00%
(valid when Pr.03-28 sets as -1010 V)
-50.00
03-73
Negative AVI Voltage
Highest Point
-10.00–0.00 V
(valid when Pr.03-28 sets as -1010 V)
-10.00
03-74
Negative AVI Proportional
Highest Point
-100.00–100.00%
(valid when Pr.03-28 sets as -1010 V)
-100.00