EasyManua.ls Logo

Delta VFD13AMS43ANSAA

Delta VFD13AMS43ANSAA
805 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 12 Descriptions of Parameter SettingsMS300
367
Fault Code
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
current
Volt.
OL
SYS
FBK
EXI
CE
27: Over torque 2 (ot2)
28: Under current (uC)
31: EEPROM read error (cF2)
33: U-phase error (cd1)
34: V-phase error (cd2)
35: W-phase error (cd3)
36: cc (current clamp) hardware error (Hd0)
37: oc (over-current) hardware error (Hd1)
40: Auto-tuning error (AUE)
41: PID loss ACI (AFE)
43: PG feedback loss (PGF2)
44: PG feedback stall (PGF3)
45: PG slip error (PGF4)
48: ACI loss (ACE)
49: External fault (EF)
50: Emergency stop (EF1)
51: External base block (bb)
52: Password is locked (Pcod)
54: Illegal command (CE1)
55: Illegal data address (CE2)
56: Illegal data value (CE3)
57: Data is written to read-only address (CE4)
58: Modbus transmission time-out (CE10)
61: Y-connection / -connection switch error
(ydc)
62: Deceleration energy backup error (dEb)
63: Over slip error (oSL)
72: STO Loss (STL1)
76: STO (STo)
77: STO Loss 2 (STL2)
78: STO Loss 3 (STL3)
79: U-phase over-current before run (Aoc)
80: V-phase over-current before run (boc)
81: W-phase over-current before run (coc)
82: U-phase output phase loss (oPL1)
83: V-phase output phase loss (oPL2)
84: W-phase output phase loss (oPL3)
87: Low frequency overload protection (oL3)
89: Rotor position detection error (roPd)

Table of Contents

Other manuals for Delta VFD13AMS43ANSAA