4-14
4-2  Detailed Description of Parameters 
00 System Parameters  a the parameter can be set during opera
tion 
 
 
Hybrid servo drive model code ID 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: Read only
 
Settings Read only 
 
 
Display of rated current of the Hybrid servo drive 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: Read only
 
Settings Read only 
  Parameter 00-00 is used to determine the capacity of the Hybrid servo motor which has been 
configured in this parameter in factory. In addition, the current value of Parameter (00-01) can be 
read out to check if it is the rated current of the corresponding model.
 
Display value of the current 
value of Parameter 00-01 for the related Parameter 00-00. 
230V Series 
Power (KW) 
5.5 7.5 11 15 18.5 22 30 37 
Horse Power (HP) 
7.5 10 15 20 25 30 40 50 
Model ID 
12 14 16 18 20 22 24 26 
 
460V Series 
Power (KW) 
5.5 7.5 11 15 18.5 22 30 37 45 55 75 
Horse Power (HP) 
7.5 10 15 20 25 30 40 50 60 75 100 
Model ID 
13 15 17 19 21 23 25 27 29 31 33 
 
 
 
Reset parameter settings 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
 
Settings 0: No function 
 
  5: Rest the kWh at drive stop 
 
  10: Reset parameter values 
  If it is necessary to restore the parameters to factory default, just set this parameter to “10”. 
 
 
Software version 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: #.## 
 
Settings 
Read only 
 
a 
 
Selection of multi-function display 
 
Control mode  VF  FOCPG  FOCPM   
  Factory default: 0 
 
Settings  0: Display the output current (A) 
U
 
 
1: Reserved 
 
 
 
2: Display the actual output frequency (H) 
U