Chapter 11 Summary of Parameter SettingsC2000 Plus
11-38
Pr. Parameter Name Setting Range Default
06-61
Software Detection GFF Filter
Time
0.00–655.35 sec. 0.10
06-62
dEb Reset Bias Level
(Applied to 230V / 460V Models)
230V models: 0.0–100 V
DC
460V models: 0.0–200.0 V
DC
20.0
40.0
06-63
Operation Time of Fault Record 1
(Days)
0–65535 days
Read
only
06-64
Operation Time of Fault Record 1
(Minutes)
0–1439 min.
Read
only
06-65
Operation Time of Fault Record 2
(Days)
0–65535 days
Read
only
06-66
Operation Time of Fault Record 2
(Minutes)
0–1439 min.
Read
only
06-67
Operation Time of Fault Record 3
(Days)
0–65535 days
Read
only
06-68
Operation Time of Fault Record 3
(Minutes)
0–1439 min.
Read
only
06-69
Operation Time of Fault Record 4
(Days)
0–65535 days
Read
only
06-70
Operation Time of Fault Record 4
(Minutes)
0–1439 min.
Read
only
06-71 Low Current Setting Level 0.0–100.0% 0.0
06-72 Low Current Detection Time 0.00–360.00 sec. 0.00
06-73 Low Current Action
0: No function
1: Fault and coast to stop
2: Fault and ramp to stop by the second deceleration
time
3: Warn and continue operation
0
06-86
PTC Type
(Applied to 230V / 460V Models)
0: PTC
1: KTY84-130
0