Chapter 12 Descriptions of Parameter SettingsMS300
300
ON: the output of the drive stops immediately and the motor is
in free run status. The drive is in output waiting status until
the
switch is turned to OFF, and then the drive restarts and runs to
the current setting frequency.
Cancel the setting of
auto-acceleration /
auto-deceleration
time
Set Pr.01-44 to one of the 01–04 setting modes before using
this function. When this function is enabled, OFF is for auto
mode and ON is for linear acceleration / deceleration.
Rotating speed
command from AVI
ON: force the source of the drive’s frequency to be AVI. If the
rotating speed commands are set to AVI and ACI at the same
time, the priority is AVI > ACI.
Rotating speed
command from ACI
ON: force the source of the drive’s frequency to be ACI. If the
rotating speed commands are set to AVI and ACI at the same
time, the priority is AVI > ACI.
ON: the drive ramps to a stop according to the Pr.07-20 setting.
ON: the frequency of the drive increases or decreases by one
unit. If this function remains ON continuously, the frequency
increases or decreases according to Pr.02-09 / Pr.02-10.
The Frequency command returns to zero when the drive stops
and the displayed frequency is 0.00 Hz. If you select Pr.11-00,
bit 7 = 1, the frequency is not saved.
ON: the PID function is disabled.
ON: the current counter value is cleared and displays 0. The
drive counts up when this function is disabled.
Input the counter
value (MI6)
ON: the counter value increases by one. Use the function with
Pr.02-19.