C-110-170-200E R11 Page 11
3. Maintenance and troubleshooting
Maintenance Schedule
Regular Service
Period as
indicated
Each
use
1
st
50hrs
Every
month /
Every
500hrs
When
neede
d
Procedure / Remarks
Check pump oil
level
Top up if necessary.
Change pump
oil
Recommended
Oil : SAE
15W40
Usage :
Approx. 0.4kg
of oil
Renewal of oil:
Turn off High Pressure Cleaner.
Loosen bolt (Hex) at bottom of pump
housing.
Drain oil into a waste oil-tray.
Tighten bolt (Hex)
Add oil through pump inlet on top of the
pump until the red point of the oil control
glass has been reached.
Notice: Do not dispose of used oil in drain.
Cleaning of
machine
Use damp cloth to wipe the cabinet and
handle bar.
Notice:
Do not use detergent cleaning chemicals
Cleaning of
motor fan
( to ensure
sufficient
airflow )
Clean the motor fan cover.
Clean the motor fan blade.
Do NOT operate the machine with
damaged or removed fan cover.