Remote IP to Ping - remote IP address to monitor via ICMP echo requests;
SNMP: Changing its bit in cfgNewMode.0
Max. Consecutive Restarts - number of consecutive resets to perform when ping timeout
is active. Value 255 disables counting (unlimited);
SNMP: cfgResetCount.0
6.10.2. ICMP Monitoring Settings
Timeout, min - the time (in minutes) since last ping request to reboot system and target.
The both ICMP modes use this shared parameter however they have separate timers;
SNMP: cfgPingTime.0 (in minutes)
Restart External Device - global flag for enable/disable the two ICMP modes. Does not
affect to the manual restart;
SNMP: Changing its bit in cfgMode.0
Restart Pulse Width, sec - defines the time of the RST pulse in seconds
SNMP: cfgResetPulse.0
Port P5 Restart Pins - bit mask to select some of P5 pins as external device restart pins.
Pins must be outputs in cfgP5Dir;
SNMP: cfgP5DupRST.0
Reset I/O Ports on Restart - if this option is enabled DAEnetIP2 v2 will set in logical "0" all
the outputs P3 and P5;
SNMP: Change its bit in cfgNewMode.0