44
2.3. About the error code
See the table below for error codes, details of faults, and coping strategies when the rmware is updated through DPMS
(Denon Product Management Server).
Error
Code
Details of Error code Display Coping strategies
01 Log-in to DPMS failed.
L o g i n f a i l e d 0 1
Reset and update again.
Carry out the update in an environment
that has little network load.
02
Line, etc., is busy when logging into
DPMS.
S e r v e r i s b u s y 0 2
Carry out the update in an environment
that has little network load.
03 Connection to DPMS failed.
C o n n e c t i o n F a i l 0 3
Check the network connection.
Carry out the update in an environment
that has little network load.
04
Firmware le data was requested but
error message was received.
C o n n e c t i o n F a i l 0 4
Check the network connection.
Carry out the update in an environment
that has little network load.
05
Firmware le data was requested but
it timed out.
C o n n e c t i o n F a i l 0 5
Check the network connection.
Carry out the update in an environment
that has little network load.
06
Firmware le data was requested but
error message was received.
C o n n e c t i o n F a i l 0 6
Check the network connection.
Carry out the update in an environment
that has little network load.
07
All rmware le data was requested
but it timed out.
C o n n e c t i o n F a i l 0 7
Check the network connection.
Carry out the update in an environment
that has little network load.
08
Firmware le data of Main CPU was
requested but error message was
received.
C o n n e c t i o n F a i l 0 8
Check the network connection.
Carry out the update in an environment
that has little network load.
09
Firmware le data of Main CPU was
requested but it timed out.
C o n n e c t i o n F a i l 0 9
Check the network connection.
Carry out the update in an environment
that has little network load.
0A
Error (NG) message was received
when rmware of Main CPU was
downloaded.
D o w n l o a d f a i l 0 A
Check the network connection.
Carry out the update in an environment
that has little network load.
0B
Error (line congestion) message was
received when rmware of Main CPU
was downloaded.
D o w n l o a d f a i l 0 B
Check the network connection.
Carry out the update in an environment
that has little network load.
0C
Error (connection failure) message
was received when rmware of Main
CPU was downloaded.
D o w n l o a d f a i l 0 C
Check the network connection.
Carry out the update in an environment
that has little network load.
0D Received Package Version is wrong.
D o w n l o a d f a i l 0 D
Check the network connection.
Carry out the update in an environment
that has little network load.
0E
Connection to DPMS failed.
(can not get NTP)
C o n n e c t i o n F a i l 0 E
Check the network connection.
Carry out the update in an environment
that has little network load.
10
Main CPU failed to receive rmware
for rewriting sent from
DM860A (when timed out).
U p d a t i n g f a i l 1 0
Turn off and on the power. Updating