6. Clearing the Operation Info
6.1. Actions
• Displays the accumulated operating time of the unit, the number of times the power was switched
on, and the number of occurrences of each protection.
6.2. Operations
Remove all input/output terminals and the AC plug.
Connect the AC plug again and place the product in standby mode.
While holding down buttons "
OPTION
" and "
DIMMER
" simultaneously, press the power button to turn
on the power.
L1
PRODUCT MODE
When "
PRODUCT MODE
" appears on the display, release the button and press the button "power"
→"
ZONE2 ON/OFF
" → "
ZONE3 ON/OFF
" to place the product in standby mode.
7. Log Capture feature
7.1. Actions
• Acquires the Network Module log.
• The log is deleted when the Network Module is deleted.
If an error occurs, it is acquired without turning off the power of this unit.
• The log can be copied to a writable USB ash drive.
It can also be sent to a server if this unit is connected to the Internet.
• The log is stored in the root folder of the USB ash drive with the name "logs-<friendlyname>-
<number>.tar.gz".
<friendlyname> indicates the friendly name and <number> indicates the sequence number.
Previous logs on the USB î™±ash drive are not overwritten. The log is encrypted.
7.2. Starting up
While the power is on, hold down buttons "
BACK
" and "
OPTION
" for at least 3 seconds.
7.2.1. If the USB î™±ash drive is connected after starting the unit
(1) The log is written to the USB î™±ash drive and "Storing Logs..." is displayed.
The log is also sent to the server.
L1
Storing Logs...
(2) When a log package is saved to a USB î™±ash drive, "USB SUCCESS" appears in the display for 5
seconds, regardless of whether the upload to the server was successful.
L1
USB SUCCESS
(3) When saving of the log package fails, "USB FAILED" appears in the display for 5 seconds, regardless
of whether the upload to the server was successful.
L1
USB FAILED
7.2.2. When the USB î™±ash drive is not connected after startup, and this
unit is connected to the Internet.
(1) The log is sent to the server and the display shows "Storing Logs..." for 5 seconds.
L1
Storing Logs...
(2) When the log package is uploaded, the ticket numbers "UPLOAD No:XXXXX" and "Push ENTER"
are displayed until RC or the "Enter" or "Back" button of this machine is pressed.
L1
TicKet No:XXXXX
L2
Push ENTER
(3) If the log package upload fails, "FAILED" is displayed for 5 seconds.
L1
FAILED
Before Servicing
This Unit
Electrical Mechanical Repair Information Updating