3. System Connector(DENON BUS) don't work
Check Power Supply Voltages for DENON BUS Check Soldering.
INPUT B'D DENON BUS BLOCK N.G INPUT B'D DENON BUS BLOCK
[WF31:13pin ST5V [WF31:13pin ST5V
MAIN B'D
[WN31:13pin ST5V
Q613
䊶䈀BN96:1pin ST6V
D607
SUB TRANS B'D
O.K.
Check Control Signal for DENON BUS Check Soldering.
INPUT B'D DENON BUS BLOCK N.G INPUT B'D DENON BUS BLOCK
[WF31:9pin BUS CLK,10pin BUS RXD_O JK31
11pin BUS TXD_O OK? Q301,Q302
[WF31] 9,10,11pin
MAIN B'D
[WN31] 9,10,11pin
IC31
[IC21]:26,27,28 pin
O.K.
END
4. The Key Operation don't work
Check Signal for KEY Check Soldering.
MAIN B'D N.G WF81,S801S809,VR81,VR82 on FRONT B'D
[IC62]3,5pin F_JOG±,21,22 VJOG± WN81,IC62 in MAIN B'D
17pin PWR_KEY,93,95pin Key 0/1 OK?
O.K.
END
5. The Remote Control Operation don't work
Check Signal for Remote Control Check Soldering.
䊶䌛IC62:73pin REMOTE on MAIN B'D N.G WF81on FRONT B'D
䊶䌛RC81:3pin Vcc 3.3V OK? WN81,IC62 in MAIN B'D
O.K.
END