16
Unit ARMED
(BLUE LED ON)
but don’t execute
trig command
Red front led BLINKING
Green front led is BLINKING
Wires error
Mains power overload
Electronic Board overheath
Bag changed, reset needed
Follow instructions Paragraph 13
Empty bag - replace it following instructions
on Paragraph 13
Unit still warming, wait max 20 min. with the unit
connected to the mains power
Refer to bag Reset (Paragraph 12)
and shooting time setting (Paragraph 11)
Warning:
please verify/set again the shooting time.
Try the Recover procedure (Paragraph 14)
With no results replace the board
Power o the unit and verify air flow near the unit
(Paragraph 14)
Verify on J10 that when alarm activates there is
a contact between - GND (6) + ARM (7)
Verify on J10 that when alarm is ON there is a
contact between - GND (Pin 6) + TRIG (Pin 8)
See time setting (Paragraph 11)
Wires error
The W1 jumper is OPEN,
unit in’ “RESET” mode
Unit cannot be
ARMED
BLU LED OFF
While setting shooting time
the green LED blinks only
once
ACTION/SIGNAL FOUND POSSIBLE CAUSE POSSIBLE SOLUTION