EasyManua.ls Logo

Denso RC5 - Input Connector CN8 (Standard Mode, NPN)

Denso RC5
176 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
When the status of the program start signal is switched from OFF to
ON with the program step-stopped, the program will resume from the
step following the suspended step and stop at the cycle end.
Single-cycle operation
At step-stop
Robot status
Program start ON (shorted)
signal (input) OFF (open)
Step-stop ON (shorted)
signal (input) OFF (open)
Operating halfway
Performing
remaining
operation
Program Start Operation-2
Caution: To cancel the execution of the remaining steps of a step-
stopped program and start it from the beginning, input a
program reset signal, a program No. select signal and a
program start signal at the same time. For further information,
refer to Subsection 6.4.5 "Program Reset (Input)".