EasyManua.ls Logo

Desa P324 - Cleaning and Maintenance; Service Hints; Technical Service

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.desatech.com
108660-01E 21
Figure 39 - Typical Flame Pattern
P325(B) and VP325(B) Models
P324 and VP324 Models
BURNER FLAME PATTERN
Burner ames will be steady; not lifting or oat-
ing. Flames should go up through the middle
of log set. Flames should not "spill" to the
edges of the pan or sides of the log set.
Figure 39 shows a typical ame pattern. If burn-
er ame pattern differs from that described:
turn appliance off (see To Turn Off Gas to
Appliance, page 20)
see Troubleshooting, page 22
INSPECTING BURNERS
Continued
CLEANING AND
MAINTENANCE
WARNING: Installation and
repairshouldbedonebyaquali-
edserviceperson.Theappli-
anceshouldbeinspectedbefore
each use and at least annually
by a qualied service person.
Morefrequentcleaningmaybe
required due to excessive lint
from carpeting, bedding mate-
rial,pethair,etc.Itisimperative
thatthecontrolcompartments,
burners,andcirculatingairsys-
tembekeptclean.
WARNING:Logscanbehot.
Handle only when cool.
WARNING: Turn off gas and
electricalpowerbeforeservicing
appliance.
PILOT AND BURNER
Remove logs and ember material before
cleaning burner and replace when cleaning
is complete.
Burner and controls should be cleaned
with compressed air to remove dust, dirt,
or lint.
Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt, or lint.
LOGS
If you remove logs for cleaning, refer to
log placement information on page 16 to
properly replace logs.
Use a vacuum cleaner to remove any
carbon buildup on logs.
Replace log(s) if broken. See Replacement
Parts, page 25.
Replace ember material periodically as
needed. See Replacement Parts, page 25.
SERVICE HINTS
When Gas Pressure Is Too Low
pilot will not stay lit
burner will have delayed ignition
replace will not produce specied heat
propane/LP gas supply may be low if using
propane/LP gas
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation, or troubleshooting. If so,
contact DESA’s Technical Service Department
at 1-866-672-6040. When calling, please
have your model and serial numbers of your
heater ready.,
You can also visit DESAs technical services
web site at www.desatech.com.