www.desatech.com
108660-01E 5
The DESA warranty will be voided by, and
DESA disclaims any responsibility for the
following actions:
A) Modication of the appliance or any of the
components.
B) Use of any component part not approved
by DESA in combination with this appli-
ance.
C) Installation and/or operation in a manner
other than instructed in this manual.
D) The burning of anything other than the
type of gas approved for use in this gas
appliance.
Installation must conform with local codes or,
in the absence of local codes, with the cur-
rent National Fuel Gas Code, ANSI Z223.1 or
with the current CAN/CSA B149 Installation
Codes.
This appliance complies with ANSI Z21.50-
2000 and CSA 2.22-2000 as Vented Gas
Fireplaces and is listed and tested by the
Canadian Standards Association to the above
test standards.
NOTICE: This appliance is not
intendedtobeusedasaprimary
source of heat.
INTRODUCTION
Continued
WARNING: Installation of
this appliance should be done
by a qualied service person
well trained in the installation of
such appliances. You will also
need a building permit from
your local Building and Safety
Commissionerbeforeinstalling
this appliance; otherwise your
insuranceco.maynotcoverthis
appliance.
CAUTION: Do not connect
appliancebeforepressuretest-
inggaspiping.Damagetogas
valvemayresultandanunsafe
conditionmaybecaused.
The appliance and it’s individual shutoff valve
must be disconnected from the gas supply
piping system during any pressure testing of
that system at test pressures in excess of 1/2
psig (3.5 kPa).
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig
(3.5 kPa).
For the purpose of input adjustment two
pressure taps (for IN and OUT pressures)
are provided on the gas control valve for test
gauge connections to the appliance.