8525-M336-O1 Rev C y SlimPRO Operation
2
WEIGHING UNIT SWITCH
The weighting unit switch is a push-button
switch located on the bottom of the scale.
Pressing the switch will toggle the weighing
units between kg (kilograms) and lb (pounds).
NOTE: The default weighing unit setting is lb.
1. With the scale off, using the end of a pen,
press the push-button.
2. The Zero weight and current weighing
unit setting will be shown on the display, e.g.
“
. kg”.
3. Press the push-button again to toggle to lb.
4. The Zero weight and new weighing unit
setting will be shown on the display,
e.g. “
. lb”.
VOICE LANGUAGE SELECTION
1. With the scale off, press and hold the button for at least 5 seconds.
2. The scale display will show the default language
0 (English).
3. Press the S or T to toggle the voice language selection between:
x
0 = English
x
*8 = Spanish
x
9 = French
x
9 = Arabic
x
3 = Hindu
x
0 = Chinese
x
# = OFF (no voice)
4. Press the
button when you have made you selection.
5. The display will change to show
03, and then turn off the scale.
NOTE: The voice language selection is saved in EEPROM, and will not change when
replacing the batteries.
LOW BATTERY
When the battery voltage has dropped too low for accurate weighing, the !6 message will
be displayed for 2 seconds and the scale will automatically turn off. Remove the old batteries
and replace with new batteries before continuing operation.