Sensing units NTC 6.8 kOhm at 25°C
NTC 10 kOhm at 25°C
NTC 12 kOhm at 25°C
NTC 15 kOhm at 25°C (Default)
NTC 33 kOhm at 25°C
NTC 47 kOhm at 25°C
Sensing values: (De-
fault NTC 15 K)
0°C
20°C
50°C
42 kOhm
18 kOhm
6 kOhm
Control PWM (Pulse Wide Modulation)
Ambient temperature 0° to +30°C
Frost protection tem-
perature
5°C to +9°C (default 5°C)
Temperature range Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. floor: 20-35°C (if unrecovera-
ble seal is broken then up to
45°C).
Min. floor: 10-35°C, only with
combination of room and floor
sensor.
DEVIreg™ Touch
Installation Guide 5