Loading...
Sensor failure moni-
toring
The thermostat has a built-in
monitoring circuit, which will
switch off the heating if the sen-
sor is disconnected or short-
circuited
Cable specification
max.
1x4 mm
2
or 2x2,5 mm
2
Ball pressure test
temperature
75°C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20°C to +65°C
IP class 21
Protection class
Class II -
Dimensions 85 x 85 x 20-24 mm (in-wall
depth: 22 mm)
Weight 103 g
Electrical safety and Electro-Magnetic Compatibility for this
product is covered by the compliance with the EN/IEC
Standard “Automatic electrical controls for household and
similar use”:
EN/IEC 60730-1 (general)
EN/IEC 60730-2-9 (thermostat)
DEVIreg™ Touch
6 Installation Guide