8514-296-001 REV A page 62
COMM
ERROR6
VFD
Communication
Fault
Condition
This error indicates that a VFD exception error is set and
there is no VFD fault in the VFD fault register and there is
no COMM ERROR 5 condition.
Delay Occurs following the “DELAY” error (see corresponding
detail)
Action Stop the machine and clear the cycle. Keep the door locked
until the machine has stopped moving and then unlock the
door.
Solution The washer will not restart until the power is removed and
re-applied.
COMM
ERROR7
Communication
Bus Error
Condition
If a state-of-health message reply is not seen by the master
microprocessor from the UC3 microprocessor after 10
minutes, the master will reset the UC3 and restart the 10
minute timer. Again, after 10 minutes, if a state-of-health
message is not received by the master, it will reset the UC3
a second time. After 10 minutes, the master will reset the
UC3 a final time and post a COMM ERROR 7.
Note: When the master resets the UC3, the control will
disconnect from the network. If the first reset is not
successful, the control will not be able to reconnect to the
network, USB or card reader functions.
Delay 3 cycles of 10 minutes (see above)
Action When detected, the washer control will stop the machine
and clear the cycle. It will keep the door locked until the
machine has stopped moving and then unlock the door.
Solution The washer will not restart until the power is removed and
re-applied.
SECONDARY
FUSE ERROR
Factory
program error
Condition
This error occurs when the fuse settings for the
Slave/Secondary microprocessor have not been set correctly
during factory programming
Delay None
Action When detected, the washer control shall not be operational.
Solution The control must be re-programmed with the factory
programming tool.
MAIN FUSE
ERROR
Factory
program error
Condition
This error occurs when the fuse settings for the Master/Main
microprocessor have not been set correctly during factory
programming
Delay None
Action When detected, the washer control shall not be operational.
Solution The control must be re-programmed with the factory
programming tool.
Note: Whenever power is turned off to the washer, it must remain off for one minute. The washer
will not operate properly if this is not done.

Table of Contents

Other manuals for Dexter Laundry A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dexter Laundry A Series and is the answer not in the manual?

Dexter Laundry A Series Specifications

General IconGeneral
BrandDexter Laundry
ModelA Series
CategoryWasher
LanguageEnglish

Related product manuals