8514-272-001 REV C page 19
Temperature Pricing Option:
This option allows the user to require additional vend amounts be added based on the drying
temperature chosen by the customer. This pricing adder is effective only for the Base Vend Price (it does not
affect the Extend Dry Price). It allows a pricing adder separate for “Medium” and “Hot” temperature settings.
Example- A store owner has programmed the control for the following:
Vend Price $1.00
Vend Time 30 minutes
Extend Dry Price $.25
Extend Dry Time 8 minutes
Medium Adder $.25
Hot Adder $.50
In this case, the Vend Price is displayed as:
$1.00 if Low Temperature is chosen
$1.25 if Medium Temperature is chosen
$1.50 if Hot Temperature is chosen
When Temperature Pricing Adders are in place (user has chosen a higher value then $0.00), if the customer
attempts to change their temperature selection from a lower temperature to a higher one during a drying cycle,
there will be no change in the temperature selection. The higher temperature buttons are disabled until the
drying cycle is complete and a new Vend Price is required.
The figure below shows the sub menu options for Temperature Pricing: