Symptom Probable Cause
Suggested
Remedy
Tumbler does not turn Drive belts Check both drive belts.
Replace if failed.
Drive motor Check capacitor and
motor. Replace if failed
Door switch Check for door closed
L.E.D on control
board. Check door
switch contacts and
adjustment. Adjust or
replace door switch.
Electronic control Is electronic control
closing motor relay to
power drive motor?
Check for motor light
on electronic control.
If no light and time
counting down, change
control. If light is on,
check for proper voltage
and wiring to motor
relay in rear control
compartment.
Motor run relay Test for proper voltage
to run relay coil, Test
output voltage of
relay when contacts
ingauged. if no voltage
replace relay.
TROUBLESHOOTING
72
Part # 8533-090-001 7/21