Symptom
Probable
Cause
Suggested Remedy
Erratic display Initial start-up If erratic on initial start-up, leave power
on for approximately one hour and check
machine operation again.
Grounding Machine must be grounded by separate
conductor back to neutral bar in breaker
box.
Program Check program and make corrections if
necessary.
Voltage spike Power down machine for 20 seconds
and repower. If no improvement, replace
control.
Manual
overtemp
tripping
frequently
Recirculating
chamber Lint
accumulation
Remove manual overtemp thermostat
and inspect in chamber for excessive
lint build up. Access also gained to this
chamber by removing recirculation duct
mounted at bottom of chamber, or the
panel inside burner chamber between
burners and rear back panel
Exhaust ducting
Excessive lint
buildup
Remove exhaust duct at rear of dryer
and inspect for excessive lint build up in
complete duct from dryer to where duct
exits building.
Clean linto of
of top heat air
chamber above
tumbler
Remove front panel completely. Be
careful of any wiring attached. Remove
heated air chamber cover and clean
above tumbler back to burner housing.
75