59
Part # 8533-083-001 1/18
MI1 MI2 MI3 MI4 MI5 MI6
(Left)
(Right)
24V ACM AVI ACI 10V M01
60 G XX
80 G XX
100 G
60 G XX
100 G XX
140 G XX
200 G
100 G XX
140 G
200 G
Max Spin
V Series Washer
Model
REMOVE Brown Jumper between MI5/M01
Default Setting (With Factory Installed Brown Jumper)
Default Setting (No Jumper Required)
Default Setting (No Jumper Required)
Jumper Terminal Locations on Variable Frequency Drive (VFD)
T-300, T-400,
T-600, T-900,
T-1200
T-350, T-450,
T-750
T-950, T-1450
MAXIMUM SPIN SPEED ADJUSTMENT:
If desired, the washer can be adjusted to limit the maximum extract spin speed for all wash cycles.
To make this adjustment, a jumper wire must either be installed or removed on the Variable Frequency
Drive (VFD), depending on the washer model and desired speed. This Dexter jumper part number 8220-
057-036 (qty. 1) is factory supplied on terminal points “10V” and “RC”. Remove this jumper to make new
jumper connections if necessary. Refer to Error! Reference source not found. for the approximate
location of the control terminations on the Variable Frequency Drive (VFD) and Error! Reference
source not found. for appropriate jumper connection points indicated with an “X” for the desired
maximum spin speed setting. If no adjustment to default spin speed is desired, do not remove or add
any wires on VFD.