XBee/XBee-PRO
®
DigiMesh 2.4 User Manual
ST
Wake Time. Set/read the wake period of the module.
For asynchronous sleep modules, this command defines
the amount of time that the
module will stay awake after receiving RF or serial data.
For synchronous sleep modules, this command defines
the amount of time that the
module will stay awake when operating in cyclic sleep
mode. This value will be adjusted
upwards automatically if it is too small to function
properly based on other settings.
0x45-0x36EE80
0x7D0 (2
seconds)
WH
Wake Host. Set/Read the wake host timer value.
If the wake host timer is set to a non-zero value, this
timer specifies a time (in
millisecond units) that the device should allow after
waking from sleep before sending
data out the UART or transmitting an I/O sample. If serial
characters are received, the
WH timer is stopped immediately.
When in synchronous sleep, the device will shorten its
sleep period by the value specified by the WH command
to ensure that it is prepared to communicate when the
network wakes up. When in this sleep mode, the device
will always stay awake for the WH time plus the amount
of time it takes to transmit a one-hop unicast to another
node.
0-0xFFFF (x
1ms)
0
AT
Command
Name and Description
Parameter
Range
Default

Table of Contents

Other manuals for Digi XBee

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBee and is the answer not in the manual?

Digi XBee Specifications

General IconGeneral
Operating Frequency2.4 GHz
RF Data Rate250 kbps
ModelXBee S2C
CategoryControl Unit
Operating Voltage2.1 to 3.6V DC
Operating Temperature-40 to +85 °C
InterfaceUART
Dimensions24.38 x 27.61 x 9.14 mm