10.1 Alarm Deviation Setpoint
If the temperature of the pit deviates above the setpoint by the alarm deviation
setpoint, the alarm will sound and the display will blink . If the temperature of
the pit deviates below the setpoint by the alarm deviation setpoint, the alarm will
sound and the display will blink .
The alarm will not sound when the control is first powered up and the pit is cold.
The alarm is only enabled once the temperature gets close to the pit temperature
setpoint. The alarm deviation is settable from 20 to 125 degrees F and the factory
default is 50 degrees F.
If the ramp feature is turned on and the pit is actively ramping, the only time that
the low alarm will become active is if the pit temperature drops 20 degrees below
the food setpoint temperature.
Pit Temperature
Gives “Hi” Alarm
Pit
Setpoint
Gives “Lo” Alarm
Deviation Alarm Setpoint
Deviation Alarm Setpoint