Page 14
The Relay is rated at 250 VAC / 30VDC @ 60W / 1500 VAC Isolation.
• Connect either J3-1 (NO) for a normally open relay or J3-3 (NC) for a
normally closed relay to the device to be controlled
• Connect J3-2 (Common) to the other side
• Ensure Relay has been properly configured in the Intercom’s Software
Configuration program
SNSR/3.3V
The IP7-FX supports an input sensor that can be used for a variety of
applications. The sensor can be defined as Active when closed to ground
or Active when open to ground via software. Digital Acoustics’
TalkMaster™ Software provides functionality for monitoring the status (open
or closed) of a door via the sensor.
• Connect J3-5 (SNSR/3.3V) and J3-6 (GND) to a door sensor or device
that can provide a contact closure
• Ensure Sensor has been configured to be Activate when closed to
ground or Activate when open to ground in the IP7-FX’s software
configuration
Optionally, this connector can be used to power an LED at 3.3V (current
limited).
• Connect J3-5 (SNSR/3.3V) to the positive side of the LED and J3-6
(GND) to the negative side
• Ensure Sensor has been configured to Activate when open to
ground in the IP7-FX’s software configuration to prevent the sensor
alert from being generated