EasyManua.ls Logo

Digitrax DS64 - DS64 Option Switch Configuration; Changing Option Switch Settings; Option Switch Settings Table

Digitrax DS64
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
©2007 Digitrax, Inc www.digitrax.com 11
The Option Switches (OpSw) are configuration switches that control features
via software within the DS64. The option switches are generally set during
the configuration process and then left alone. The DS64 is designed to
‘remember the OpSw switch settings you set.
How to change the settings of your DS64’s Option Switches (OpSw)
1. Begin with your DS64 powered up and connected to the track. Turnouts can
be either connected or not.
2. On the DS64 press and hold the OPS button down for about 3 seconds until
the red OPS LED and green ID LED begin to blink alternately. This indi-
cates that the DS64 is ready to change the option switches
2
2
4
4
4
4
3
3
T
T
r
r
a
a
n
n
s
s
m
m
i
i
t
t
t
t
e
e
r
r
R
R
d
d
T
T
8
8
5
5
0
0
-
-
8
8
7
7
2
2
-
-
9
9
8
8
9
9
0
0
P
P
a
a
n
n
a
a
m
m
a
a
C
C
i
i
t
t
y
y
,
,
F
F
L
L
U
U
S
S
A
A
3
3
2
2
4
4
0
0
4
4
F
F
8
8
5
5
0
0
-
-
8
8
7
7
2
2
-
-
9
9
5
5
5
5
7
7
w
w
w
w
w
w
.
.
d
d
i
i
g
g
i
i
t
t
r
r
a
a
x
x
.
.
c
c
o
o
m
m
E
E
s
s
a
a
l
l
e
e
s
s
@
@
d
d
i
i
g
g
i
i
t
t
r
r
a
a
x
x
.
.
c
c
o
o
m
m
The following table shows the factory default settings (Thrown) for the DS64.
Option Switches (OpSw):
OpSw Table Settings for the DS64
OpSw
Description
Thrown State (Factory Default)
Description
Closed State
01
Pulse Enabled for Solenoid Devices
Static Output for Slow Motion Devices
02
Disabled
Pulse Timeout 200ms
03
Disabled
Pulse Timeout 400ms
04
Disabled
Pulse Timeout 800ms
05
Disabled
Pulse Timeout 1600ms
06
Output Auto Power Up
Disabled
07
N/A
Reset to Factory Default
08
Regular Startup Delay
65ms x Output #1 Address
Startup Delay Doubled
09
Timeout disabled
16 second timeout for static output
10
Throttle and computer commands
accepted
Computer commands only accepted
11
Function not yet implemented
12
The “A” input is set for Sensor only
The “S” input toggles the Output
The “A” input if High, forces the Output
to Thrown, the “S” input if High, forces
the Output to Closed.
13
Disabled
All Inputs are Set for Sensors & also
control Outputs per OpSw 12 setting
14
Allow commands from LocoNet and
Track
Allow Commands from Track Only
15
Function not yet implemented
16
Enable operation of routes
Disable operation of routes
17
Disabled
Enable Crossing Gate Function for
Output ‘1’
18
Disabled
Enable Crossing Gate Function for
Output ‘2’
19
Disabled
Enable Crossing Gate Function for
Output ‘3’
20
Disabled
Enable Crossing Gate Function for
Output ‘4’
21
Generate LocoNet General Sensor
messages
Generate LocoNet Turnout State
messages

Related product manuals