8
LOW WATER / REFILLING THE WATER TANKS
When the water tanks have emptied and the water level in the product is getting low, the product will ash its LEDs twice
and beep twice. The product will operate for a further 15 minutes before beeping once and switching into low water
mode. For products being operated with the LED log fuel bed, only the fuel bed will remain illuminated while in low water
mode. At this point, the product can either be switched into stand-by mode using the remote control or Bluetooth receiver
or the product can be relled with water. Relling the product with water will cause the product to restart automatically.
To rell the tank, remove the fuel bed and remove the water tank from its position on top of the sump. Rell the water tank
using ltered/decalcied water only. The tank can then be replaced on top of the sump. If the product was not switched
into stand-by mode after experiencing low later, the product will restart automatically after about 20 seconds of relling.
MAINTENANCE
GENERAL TIPS
Only use ltered/decalcied water in this appliance.
Always ensure that the appliance is sitting on a level surface.
If you intend not using the appliance for longer than a week, remove and empty the sump and water tank.
Once installed, never move this appliance or lay on its back, without draining the water from sump.
CLEANING
WARNING: Always press Switch ‘A’ to the ‘OFF’ (0) position (Fig 10A) and disconnect from the power supply before
cleaning the re.
We recommend cleaning the following components once every week, particularly in hard water areas:
Sump, Nozzle, Tank cap and seal, Air lter
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or u, the soft brush attachment of a vacuum cleaner should occasionally be used.
SUMP
1. Open the drawer & press switch ‘A’ to the ‘OFF’ (0) position (Fig 10A)
2. Remove the water tank from its position on top of the sump.
3. Disconnect the electrical connector to the transducers, located on the right side of the sump. (Fig 14).
4. There are two orange clips holding down the nozzle on the sump; one on the left and one on the right hand side of
the nozzle. On the left side, press in the clip with one hand and with the other lift the nozzle out of the clip. Repeat
this for the right side (Fig 15). The nozzle can now be lifted up and placed aside (Fig 16).
5. Gently lift up the sump (Fig 17), taking care to keep it level so as not to spill any water. Sit the sump in the sink.
6. Carefully empty the sump into the sink taking note that the transducer is held in place by a retaining clip.
7. Put a small amount of washing up liquid into the sump, and using a soft brush, gently clean all surfaces in the sump
and gently clean the transducer including the cone and metal discs located in the top grooved surface.
8. When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
9. Clean the nozzle with a soft brush and ush out thoroughly with water.
10. Reverse the above steps 1 – 6 to reassemble.
TRANSDUCER
The transducer is a consumable item and may need to be replaced through time, depending on its usage. Replacement
transducers can be purchased from our your dealer. The transducer is xed in the sump with a plastic clip. If you need
to replace your transducer:
1. Follow the steps 1-5 in the CLEANING - Sump section under ‘Maintenance’ to gain access to the transducer.
2. Press the clip back and lift the transducer upwards out of its holder.
3. Place the new transducer into the sump, ensuring the its cable does not sit over the cone.
4. Reverse the above steps to reassemble the nozzle and sump.
AIR FILTER
1. Open the drawer to access the air lter at the rear of the module.
2. Gently slide the air lter upwards out of its plastic holder. (Fig 18)
3. Gently rinse with water in the sink and dry with fabric towel.
4. Replace the lter making sure that the coarse black lter is facing outwards.
5. Replace the fuel bed.