- 14 -
The heater must be securely fixed to a wall. Screws with suitable wall fixings for solid walls are provided. If other
wall types are encountered it is the installer who must choose the most suitable fixing.
SUGGESTED FIXINGS
SOLID BRICK/BLOCK: No. 10 size high temperature resistant plastic inserts, 8mm drill bit. Drill hole 15mm deeper
than plastic insert length.
PLASTERBOARD - If possible locate studding and use No. 10 woodscrews directly into the wood, otherwise M5
rawlplug intersets are suitable.
If the floor is carpeted then the carpet should be slit and underlay cut away to allow the feet to rest firmly on the
floor. Carpet gripper must be locally removed so that the feet may rest in a level position. To maintain stability, it
is essential that the heater is placed on a level surface and care should be taken to avoid irregular surfaces, such as
may result from carpets or tiled surrounds partially protruding under the heater.
This Heater is rated IPX4
DO NOT UNDER ANY CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT
SEEKING EXPERT ADVICE. THE HEATER SHOULD NEVER BE FREED FROM THE WALL WITH ENERGY
CELLS INSIDE.
USE CAUTION WHEN INSTALLING THIS PRODUCT, UNPAINTED METALWORK CAN HAVE SHARP
EDGES.
Installing the Heater
IMPORTANT Head of wall fixing screw must be flanged pan head type and have a diameter no less than 11mm. No
countersunk headed screws to be used for wall fixing.
NOTE:
For other wall types (e.g. timber frame and hollow concrete), seek specialist advice.
NOTE:
ANY FIXING DROPPED INTO HEATER MUST BE RETRIEVED AS THEY MAY IMPACT PRODUCT SAFETY
DURING OERATION
The appliance must be securely fixed to the wall. The installed appliance
could weigh up to 165kg and if it falls o the wall it could cause severe
personal injury or death. It is the responsibility of the installer to ensure
that the appropriate wall fixing is used and that the floor is capable or
bearing the full weight.
WARNING
To avoid the risk of fire keep all combustible materials, such as furniture,
pillows, bedding, papers, clothes and curtains away from the heater –
minimum clearances are shown in Fig. 1.
WARNING