- 31 -
These settings can be used to significantly change the operation of the heater. While useful for very specific
requirements, there is a much higher risk of User error and unintended consequences of changing these settings
compared to the top-level settings menu. It is recommended that these settings are only modified by trained
professionals.
To navigate to the Advanced Settings menu, from the home screen:
Press and hold Advance and Menu buttons for 5 seconds.
Each of the following headings relate to an item in the settings menu.
Temp Settings
Charging Settings
If the output of the storage heater is not able to deliver the required heat demand throughout the day, it is
possible to force the heater to store additional energy. This will manually adjust the charge calculation to store
more electrical energy during the charging period.
This setting displays the available charge times for the Heater to store o-peak energy. It is presented like the
Timer setup screen, but without a Target Temperature or Day Selection. This allows the Installer to set up to 4
charging On and O times.
Charge Times
This setting displays the available charge times for the Heater to store o-peak energy. It is presented like the
Timer setup screen, but without a Target Temperature or Day Selection. This allows the Installer to set up to 4
charging On and O times.
Charge times should remain at the default settings (as shown above) for twin supply installations. This setting
should only be used in single supply installations. Values entered here always take precedent.
Advanced Settings
Temp Units (Temperature Units)
This setting defines which temperature units are displayed on the heater. The default is °C, but °F can
be set. When °F is selected, the heater will convert °C values to °F and round to the nearest number.
Default charge times (Standalone) are:
Period 1 00:00 - 00:00
Period 2 00:00 - 00:00
Period 3 00:00 - 00:00
Period 4 00:00 - 00:00

Other manuals for Dimplex Quantum series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dimplex Quantum series and is the answer not in the manual?

Dimplex Quantum series Specifications

General IconGeneral
BrandDimplex
ModelQuantum series
CategoryHeater
LanguageEnglish

Related product manuals