- 32 -
Service Settings
These items are for use by service personnel only. The settings eect the accuracy and energy usage of the heater
and should only be modified by a professional.
Heat Source Setting
With this setting, it is possible to restrict use of peak rate energy for each of the following modes:
- Timer Mode
- Boost Mode
- Setback Mode
Factory Reset
This setting allows the User to restore the default values to all settings. Returning the product to the same state
that it left the factory.
NOTE:
Increased use of peak rate electricity could lead to increased running costs
Room Temp (Temperature) Oset
Allows the manual adjustment of electronic room thermostat reading by +/-3.0°C
Slave Heater Mode
This setting modifies the charge algorithm to prevent under-charging when enabled. If more than one
heater is installed in the same room, it is recommended that the smallest capacity heater(s) is set as a
slave. This is disabled by default.