Do you have a question about the DINA DNSL-ZM and is the answer not in the manual?
Describes the intended application and testing basis for SAFELINE modules.
Covers crucial system validation, responsibility, and environmental conditions for safe operation.
Explains how the central module behaves during errors and how to resolve them.
Details the schematic representation and terminal layout for central modules.
Provides visual identification and terminal layout for various central modules.
Illustrates the wiring, display, and front view for standstill and speed monitoring modules.
Shows the wiring, display, and front view for input and output modules.
Describes monitoring up to eight shutdown mats and activating quit-functions.
Explains the function mode switch inputs at the central module for different modes.
Details inputs for two-hand functions according to EN 574 Type IIIC.
Covers safety circuit inputs requiring manual acknowledgement.
Describes safety circuit inputs that do not require manual acknowledgement.
Explains quit functions for safety circuits on central and function modules.
Covers 2-safe monitoring for standstill and motion using two axles and sensors.
Specifies requirements for proximity sensors used in monitoring systems.
Details 2-safe monitoring for standstill, speed, position, and direction using Sin/Cos or TTL.
Outlines requirements for measuring systems, including Sin/Cos, TTL, and HTL types.
Explains monitoring using two PNP sensors with antivalent signals for direction sensing.
Covers 2-safe monitoring for standstill, position, direction, break, and speed with Resolver systems.
Details 2-safe monitoring for standstill, position, direction, break, and speed with SSI interface systems.
Describes the quit function for speed monitoring, including RTDS symbol and SSM signals.
Explains brake monitoring using the SAR output for ramp monitoring of an axle.
Covers direction monitoring using virtual outputs (SDI) and hardware inputs.
Enables monitoring of up to 48 different speeds for peripheral speed applications.
Describes analogue voltage input UA for selecting up to 8 speeds in DNCO functions.
Details electrical parameters like voltage, current consumption, and operating conditions.
Specifies performance levels and current ratings for semiconductor outputs on central modules.
Lists performance levels and current ratings for semiconductor outputs on function modules.
Details switching capacities, electrical life, and contact ratings for SAFELINE contact outputs.
Provides data on the electrical life of contact outputs under various load conditions.
Lists available rack sizes and the modules they can accommodate.
| Brand | DINA |
|---|---|
| Model | DNSL-ZM |
| Category | Control Unit |
| Language | English |