Systems and Equipment - 133 JT30 /JT30 All Terrain Operator’s Manual
Electric Strike System
CMW
Assemble Voltage Detector
1. Drive voltage stake into ground at least 6’ (2 m)
away from any part of system.
2. Clip voltage limiter to voltage stake.
Test Strike System
If system fails any part of this test, see “Troubleshoot Strike System” on the following page. Do not drill until
test is completed successfully.
1. Turn on drilling unit.
2. ESID control module will perform internal tests which check everything but alarms and strobe.
3. On Information Center, press F2 (Module), then F4 (ESID), and then F2 (Test) to perform total test of
strike system. During this test:
ESID bar graph in upper right corner of Information Center display should turn on (black).
Alphanumeric readout (ESID, Volts and Amps) should display numbers.
Alarms and strobes on all connected units should sound.
If this test is successful, no diagnostic codes will be displayed or recorded under Codes (F4) in
ESID.
4. Use Electric Strike Simulator to test voltage and current sensors. See page 136.