DITEC Entrematic ENERGY 47E - User Manual

DITEC Entrematic ENERGY 47E
48 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DITEC S.p.A.
Via Mons. Banfi , 3 - 21042 Caronno Pertusella (VA) - ITALY
Tel. +39 02 963911 - Fax +39 02 9650314
www.ditec.it - ditec@ditecva.com
ISO 9001
Cert. n°0957
Manuale di installazione,
manutenzione, uso.
(Istruzioni originali)
Installation manual,
main te nance
, use.
(Original instructions)
ENERGY
0DT828 - rev. 14-09-2011
IT
EN

Questions and Answers

  • L
    Luis RoyAug 5, 2025
    Why DITEC Entrematic ENERGY 47E Door Opening System curtain and motor do not move?
    • L
      lauriechavezAug 5, 2025
      The curtain and motor might not move due to several reasons: * A mains power failure or blown fuses F1, F2, or F3. * The stop being activated (indicated by the “Stop” LED on the keyboard being ON). * Incorrect motor connection to terminals or the switch being in the wrong position. * The opening (A) and closing (C) limit dip-switches being activated (LEDs 11 and 12 ON). * The motor with thermal switch activated (LEDs 11 and 12 ON). * The safety switch of the manual rod being activated (LEDs 11 and 12 ON). * A fault in one of the power devices, such as the control unit, motor, or motor cabling.
  • H
    hicksmichaelAug 9, 2025
    What to do if DITEC Door Opening System motor turns in the opposite direction?
    • S
      sarahbakerAug 10, 2025
      Reverse the two phases of the mains power supply.
  • S
    Sandra HernandezAug 13, 2025
    Why DITEC Entrematic ENERGY 47E Door Opening System door does not close automatically after closing time TC?
    • J
      John FrazierAug 13, 2025
      The door might not close automatically because: * The automatic closure enable signal has not been carried out properly (connection 1-2). * Opening command always activated (led IN always ON). * Self-test of the safety device failed (led Stop on the keyboard OFF and led SA flashing).
  • C
    Cristina WadeAug 18, 2025
    Why DITEC Door Opening System motor does not move?
    • M
      Margaret BarnesAug 18, 2025
      The motor may not move because: * The closing command is not correctly connected or is faulty (led IN does not switch ON). * Safety device activated (led “Stop” flashing on the keyboard and led SA fixed ON). * The closing limit switch (C) is activated (led 11 fixed in ON). * Opening command always activated (led IN always ON). * Self-test of the safety device failed (led Stop on the keyboard OFF and led SA flashing).
  • S
    sarah19Aug 22, 2025
    Why DITEC Door Opening System curtain doesn't stop regularly at the limitswitch?
    • B
      Bruce GoodAug 22, 2025
      The curtain might not stop regularly at the limit switch because dip-switch 5 is in the OFF position or the fuse F5 is faulty.
  • R
    Robert WilliamsAug 27, 2025
    Why DITEC Door Opening System motor stops with delay?
    • C
      coopercathyAug 27, 2025
      The motor brake may be worn-out or faulty.
  • R
    Ryan CalderonAug 31, 2025
    Why DITEC Door Opening System motor movement stops?
    • R
      robert60Aug 31, 2025
      The motor movement may stop (and the door doesn’t open completely) if input 17 is closed to 0 (led 17 OFF).

Summary

DITEC ENERGY Door Manual Introduction

Purpose and Content Overview

Introduces the manual's scope, covering installation, maintenance, and use of the ENERGY door.

General Safety Precautions

Technical Characteristics

Control Panel Specifications (49 E & 47 E)

Details electrical specs like power supply, motor rating, and protection class for 49E and 47E panels.

Mechanical Installation

Component Assembly and Mounting Procedures

Step-by-step guide for installing uprights, crosspiece, curtain, and gearmotor.

Electric Connections

Wiring Control Panel, Motor, and Safety Devices

Instructions for connecting the control panel, motor, and safety photocells.

Electronic Control Panel

49 E Control Panel: Connections and Settings

Configuration of inputs, outputs, DIP switches, and jumpers for the 49E electronic control panel.

47 E Control Panel: Connections and Settings

Configuration of inputs, outputs, DIP switches, and trimmer settings for the 47E electronic control panel.

Adjusting and Starting

Movement Direction and Safety Edge Calibration

Calibrating movement direction and adjusting cable safety edges for proper operation.

Troubleshooting

Diagnosing and Resolving Operational Issues

Table of common commands, troubles, and verification steps for fault finding.

Maintenance

6-Month Maintenance Plan and Procedures

Recommended intervals for checking and replacing door components for preventive maintenance.

Use Instructions

Operating the Door and Safety Guidelines

Information on using buttons, manual operation, and safety during door usage.

Applications and Compliance

EC Declaration of Conformity and Product Use

Details product applications, conformity to EC directives, and relevant safety standards.

DITEC Entrematic ENERGY 47E Specifications

General IconGeneral
BrandDITEC
ModelEntrematic ENERGY 47E
CategoryDoor Opening System
LanguageEnglish