Ditec DAS200T
DAS200TRF-DAS200TRG
Sliding doors automation
(Original instructions)
Technical manual
IP2348EN • 2020-10-07
www.ditecentrematic.com

Table of Contents

Questions and Answers

  • J
    Jacob JohnsonAug 6, 2025
    What to do if my DITEC DAS200TRF doesn't open and the motor doesn't start?
    • M
      moliverAug 7, 2025
      If your DITEC Door Opening System doesn't open and the motor remains inactive, first check the functions selector switch settings and change them if necessary. Then, ensure that the sensor's detection path is clear of any obstructions. Finally, verify that the power supply switch inside the building is on.
  • R
    Rachel MartinezAug 14, 2025
    Why does my DITEC DAS200TRF automation not close?
    • J
      Jacqueline Keith MDAug 14, 2025
      If your DITEC Door Opening System is not closing, check the functions selector switch settings and change them if necessary. Also, ensure that there are no objects obstructing the sensor's detection path.
  • D
    Denise Alvarez PhDAug 20, 2025
    What to do if my DITEC DAS200TRF Door Opening System opens and closes by itself?
    • T
      thomas94Aug 20, 2025
      If your DITEC Door Opening System is opening and closing on its own, ensure that there are no moving elements within the sensor's detection area.
  • M
    Marie FrazierAug 28, 2025
    What to do if the motor starts but the DITEC DAS200TRF doesn't open?
    • K
      Kathleen ShermanAug 28, 2025
      If the motor of your DITEC Door Opening System starts but the door doesn't open, check for any locks and release them. Also, make sure there are no objects preventing the door from opening.

Summary

General Safety Precautions

Declaration of Incorporation

Technical Data

Standard Installation

Main Components

Installing the Automation

Removing the Cover

Step-by-step guide for removing the main automation cover.

Side Presence Sensor Cover Removal

Procedure for removing cover with side presence sensor.

Removing the Front Casing

Instructions for detaching the front casing of the automation.

Rear Operator Installation

Guide for mounting the operator at the rear of the door.

Front Operator Installation

Guide for mounting the operator at the front of the door.

Wing Anchoring Bracket Examples

Examples of installing wing anchoring brackets.

Installing;Removing the Cover

Instructions for installing and removing a specific cover.

Example of Box Fastening

Examples with DASTAC16 Bracket

Box fastening examples using DASTAC16 wing connection bracket.

Example with DAST30 Bracket

Box fastening example using DAST30 wing connection bracket.

Example with DASTAC Bracket

Box fastening example using DASTAC wing connection bracket.

Preparation of the Glass Door Wing

Installing and Adjusting Door Wings

Procedures for fitting and aligning the glass door wings.

Floor Guide Installation

Guidelines for installing floor guides for door wings.

Belt Stop Installation

Steps for correctly installing the belt stop mechanism.

Belt Tension Check and Adjustment

How to check and adjust the belt tension for proper operation.

Sensor Positioning on Cover

Guidance on placing sensors on the automation cover.

External Sensor Cable Fixing

Method for securing external sensor cables.

Electrical Connections

Standard Electrical Connections

Basic wiring procedures for the automation system.

Control Panel Commands

Overview of commands and terminal functions on the control panel.

DAS902 MP Plus Module

Features and functions of the optional DAS902MP module.

DAS902 MP Commands

Specific commands for the DAS902MP module.

Adjustment and Control Function Selection

Display Test Procedure

How to perform a diagnostic test on the control panel display.

Status Indication on Display

Understanding the meaning of different status codes shown on the display.

Start Up

Parameters

Configuration Parameters by Function

Detailed list of parameters and their functional settings.

Main Control Board Parameters

Key parameters configurable on the main control board.

Example of Connection

Combined Opening;Safety Sensor Connection

Wiring for combined opening and safety sensors.

Interconnection of Operators

Procedures for connecting multiple operators together.

Operation Mode Selector (OMS) Functionality

How to configure and use the operation mode selector.

Synchronization

Setting up two operators to work in sync.

Interlock Functionality

Configuring doors to open sequentially.

Troubleshooting

Active Error Indication

Guide to interpreting error codes and their causes.

Routine Maintenance Plan

DITEC DAS200TRF Specifications