LEARN / EXIT SELECT
UP
DOWN
30
EN
IP2348EN
9. Adjustment and selection of control functions
The control panel has a two-figure display that displays text and/or numbers.
It has four buttons. (MMI)
The procedure to switch on the display is as follows:
press the 2-SELECT key to launch the display test
NOTE: make sure all seven segments of the two displays light up correctly to avoid
incorrect reading.
i
- 1 UP: to increase the parameter number or value in it;
- 2 SELECT: to enter a parameter or value to be programmed in the memory;
- 3 DOWN: to decrease the parameter number or value in it;
- 4 LEAR/EXIT:
• LEARN has 3 functions: 1, 2, 3.
1. Quick learning. If pressed for longer than 1 second but less than 2, the electronic
accessories connected to the control board are recognised.
2. Normal learning. If pressed for longer than 2 seconds, the display flashes . Two
seconds after releasing the button, a complete learning cycle begins which performs an
opening and closing operation to carry out the operations described in chapter 8.
3. Restore factory settings. If pressed for longer than 10 seconds, the control panel re-
stores the factory settings .
• EXIT quits the parameter menu or value without saving the changes. If EXIT is not
pressed, the control panel returns to the default display after 3 minutes of inactivity.
NOTE: the set value is stored by the control panel by pressing SELECT irrespective of whe-
ther the value has been modified or not. Press EXIT if you do not want to store the value.
i
When a value is programmed, that parameter is excluded from the learning cycle. Even if a new
learning cycle is executed, that value will not be modified.
To include the parameters in the learning cycle again, the factory settings must be set.