Questions and Answers

  • G
    gmilesAug 1, 2025
    Why DITEC Entrematic ENERGY 49E Door Opening System curtain and motor do not move?
    • J
      Jacob LawrenceAug 1, 2025
      The curtain and motor might not move due to several reasons: * A mains power failure or blown fuses F1, F2, or F3. * The stop being activated (indicated by the “Stop” LED on the keyboard being ON). * Incorrect motor connection to terminals or the switch being in the wrong position. * The opening (A) and closing (C) limit dip-switches being activated (LEDs 11 and 12 ON). * The motor with thermal switch activated (LEDs 11 and 12 ON). * The safety switch of the manual rod being activated (LEDs 11 and 12 ON). * A fault in one of the power devices, such as the control unit, motor, or motor cabling.
  • J
    Jennifer FerrellAug 5, 2025
    What to do if DITEC Entrematic ENERGY 49E motor turns in the opposite direction?
    • V
      Victoria SchmidtAug 6, 2025
      Reverse the two phases of the mains power supply.
  • M
    Matthew SmithAug 9, 2025
    Why DITEC Entrematic ENERGY 49E Door Opening System door does not close automatically after closing time TC?
    • K
      kaylasullivanAug 10, 2025
      The door might not close automatically because: * The automatic closure enable signal has not been carried out properly (connection 1-2). * Opening command always activated (led IN always ON). * Self-test of the safety device failed (led Stop on the keyboard OFF and led SA flashing).
  • N
    Nicole JacksonAug 14, 2025
    Why DITEC Entrematic ENERGY 49E Door Opening System motor does not move?
    • A
      Anna JonesAug 14, 2025
      The motor may not move because: * The closing command is not correctly connected or is faulty (led IN does not switch ON). * Safety device activated (led “Stop” flashing on the keyboard and led SA fixed ON). * The closing limit switch (C) is activated (led 11 fixed in ON). * Opening command always activated (led IN always ON). * Self-test of the safety device failed (led Stop on the keyboard OFF and led SA flashing).
  • M
    Michelle JohnsonAug 18, 2025
    Why DITEC Entrematic ENERGY 49E curtain doesn't stop regularly at the limitswitch?
    • S
      seansmithAug 18, 2025
      The curtain might not stop regularly at the limit switch because dip-switch 5 is in the OFF position or the fuse F5 is faulty.
  • F
    Frank OdomAug 23, 2025
    Why DITEC Entrematic ENERGY 49E motor stops with delay?
    • R
      Ronald FisherAug 23, 2025
      The motor brake may be worn-out or faulty.
  • D
    Donald ClarkAug 27, 2025
    Why DITEC Door Opening System motor movement stops?
    • D
      Danielle LesterAug 27, 2025
      The motor movement may stop (and the door doesn’t open completely) if input 17 is closed to 0 (led 17 OFF).

Summary

General Safety Precautions

Mechanical Installation

Structural Assembly

Mounting uprights and assembling the crosspiece.

Curtain and Motor Installation

Installing the curtain, belts, and gearmotor.

Safety Device Installation

Installing photocells and safety edge.

Electric Connections

Control Panel and Motor Wiring

Connecting the control panel, motor, and security devices.

Safety Photocell Wiring

Wiring and connecting safety photocells.

49 E Electronic Control Panel Connections

49 E Signals and Setting

Trimmer and Dip-Switch Settings

Configuring automatic closing, partial opening, and functions.

49 E Control Panel Configuration

49 E Electronic Control Panel Adjustment

47 E (Inverter) Control Panel Connections

47 E Signals and Setting

47 E Control Panel Adjustment

Checking and Starting

Troubleshooting

DITEC Entrematic ENERGY 49E Specifications

General IconGeneral
BrandDITEC
ModelEntrematic ENERGY 49E
CategoryDoor Opening System
LanguageEnglish

Related product manuals