Operating instructions cod. 1592001300
1592001300 XC440C gb r1.0 07.06.2004.doc rel. 1.0
Pa
e
12 / 28
10. Use of the programming “HOT KEY “
10.1 How to program a hot key from the instrument (UPLOAD)
1. Program one controller with the front keypad.
2. When the controller is ON, insert the “
Hot key
” and push
9
9
key; the
"uPL"
message
appears followed a by flashing
“End”
3. Push “
SET”
key and the
End
will stop flashing.
4. Turn OFF the instrument remove the
“Hot Key”,
then turn it ON again.
NOTE
: the “
Err
” message is displayed for failed programming. In this case push again
9
9
key if
you want to restart the upload again or remove the “
Hot key
” to abort the operation.
10.2 How to program an instrument using a hot key
(DOWNLOAD)
1. Turn OFF the instrument.
2. Insert a
programmed “Hot Key” into the 5 PIN receptacle
and then turn the Controller
ON.
3. Automatically the parameter list of the
“Hot Key”
is downloaded into the Controller
memory, the “
doL
” message is blinking followed a by flashing
“End”.
4. After 10 seconds the instrument will restart working with the new parameters.
5. Remove the
“Hot Key”.
.
NOTE
the message “
Err
” is displayed for failed programming. In this case turn the unit off and
then on if you want to restart the download again or remove the “
Hot key
” to abort the
operation.
The unit can UPLOAD or DOWNLOAD the parameter list from its own E2 internal memory to
the
“Hot Key”
and vice-versa.
11. Keyboard locking
11.1 How to lock the keyboard
1. Keep the
9
9
and
8
8
ke
s pressed to
ether for more than 3 s the
9
9
and
8
8
keys.
2. The “POF” messa
e will be displa
ed and the ke
board is locked. At
this point it is onl
possible to view the set point or enter the HACCP
menu.
11.2 To unlock the keyboard
Keep the
9
9
and
8
8
keys pressed together for more than 3s till the “
POn”
flashing message
appears.