General IconGeneral
SeriesXLR
InputsUp to 4
Communication ProtocolModBUS RTU
BuzzerYes
Output TypeRelay
TypeController
Protection ratingIP20

Summary

General Warning and Safety Precautions

Safety Precautions

Lists critical safety measures to follow before and during instrument operation and maintenance.

General Description of Cool Mate Controllers

Models XLR130 and XLR170 Overview

Overview of the microprocessor-based controllers for refrigerating units, highlighting features and outputs.

Controlling Loads and Functions

3.3 Defrost

Details defrost control modes, including timed defrost for XLR130 and heater/hot gas for XLR170.

Keyboard Operation and Interface

Keyboard Button Functions

Details the functions of individual keys (SET, UP, DOWN, AUX, ON/OFF) for operation and programming.

Keyboard Key Combinations

Explains how to perform specific actions like locking/unlocking the keyboard and entering programming mode.

4.5 See and Modify the Set Point

Steps to display and change the target temperature set point using the SET and arrow keys.

4.7 Enter Parameter List PR1

Steps to access user-accessible parameters (PR1) by combining SET and DOWN keys.

4.8 Enter Parameter List PR2

Instructions to access the protected parameter list (PR2) via PR1 and a security code.

4.9 Change Parameter Value

General procedure for modifying any parameter value using SET and arrow keys.

Parameter List and Definitions

Regulation Parameters

Lists and defines parameters related to temperature regulation, differentials, and set point limits.

Defrost Parameters

Lists and defines parameters related to defrost type, mode, timing, and termination.

Fan Parameters

Lists and defines parameters for fan operation modes, delays, and stop temperatures.

Alarm Parameters

Defines parameters for temperature alarms, delays, and fan regulation set points.

Digital Inputs Parameters

Defines parameters for configuring digital inputs like door switch, generic alarm, and energy saving.

Auxiliary Relay Configuration Parameters

Defines parameters for configuring the auxiliary relay's function (alarm, fan, light, etc.).

Defrost Times Parameters

Defines parameters for setting workday and holiday defrost start times.

Hot Key Usage for Programming

Alarm Signals and Recovery

Alarm Message and Cause Table

Lists alarm messages, their causes, and the corresponding output actions.

Technical Data and Specifications

General Specifications

Provides housing, dimensions, mounting, protection, connections, power supply, and display details.

Connections Diagrams

15.1 XLR130 Connections

Diagrams showing terminal connections for the XLR130 model, including free voltage and direct load connections.

15.2 XLR170 Connections

Diagrams showing terminal connections for the XLR170 model, including free voltage and direct load connections.

Default Setting Values

Regulation Default Values

Lists default values for regulation parameters like Set point, Differential, and limits.

Defrost Default Values

Lists default values for defrost parameters including type, mode, termination, and interval.

Alarms Default Values

Lists default values for alarm parameters like temperature limits and delays.

Digital Inputs Default Values

Lists default values for digital input configuration, polarity, and alarm delay.