Dometic
®
MANUAL
Refrigerators
5
AMES/AES Refrigerator Models including: S1521, S1531, S1621, S1631, S1821, S1831, RM2607,
RM2611, RM2807, RM2811, RM3607 and RM3807, the ROYALE/ELITE Refrigerator Models including
RM3662, RM3663, RM3862, RM3863, RM4872, RM4873, RM7732, RM7832, RM7130, and RM7030 with
Product No. 921890401.
1. No operation - no panel lights Operation 1D-5D 40-47
DC Volts 11D 48-49
Fuse 13D 53
Wiring B 15,16,17,22,23,24
Upper Circuit Board 12D 51
Lower Circuit Board 13D 52,53
2. No operation - has panel lights Operation 1D-5D 40-47
DC Volts 11D 48,49
Thermistor 9D 48
Fuses 13D 53
Upper Circuit Board 12D 51
Wiring B 15,16,17,22,23,24
Lower Circuit Board 13D 52,53
3. No AC operation - operates on other Operation 1D-5D 40-47
mode(s) AC Volts 6D 47
Fuse 13D 53
Heating Element 7D 47
Upper Circuit Board 12D 51
Wiring B 15,16,17,22,23,24
Lower Circuit Board 13D 52,53
4. No DC operation - operates on other Operation 1D-5D 40-47
mode(s) DC Volts 11D 48,49
Fuse 13D 53
Heating Element 8D 47
Upper Circuit Board 12D 51
Wiring B 15,16,17,22,23,24
Lower Circuit Board 13D 52,53
5. No Gas operation - operates on other Operation 1D-5D 40-47
mode(s) LP Gas 1A 12
Manual Gas Valve 2A 12
Igniter 12D 50
High Voltage Cable 12D 50
Electrode 12D 50
Solenoid 12D 49
Upper Circuit Board 12D 51
Wiring B 15,16,17,22,23,24
Lower Circuit Board 13D 52,53
6. Insufficient cooling on all modes. Ventilation 2J 89
Leveling 1J 89
Ambient Temperature 5J 90
Air Leaks 3J 89
Thermistor 9D 48
Cooling Unit 6J 90
Thermistor Adjuster 10D 48
SYMPTOM CAUSE REFER TO SEC. PAGE
REFRIGERATOR SECTION