38
Dometic
®
MANUAL
Refrigerators
19C. OPERATION FOR REFRIGERATORS WITH BOTTOM MOUNT CONTROLS
CONTROLS
A
B
E
C
D
A
B
C
E
Refrigerators with Automatic Reigniters
(RM2510/RM2610/RM2810)
To start the refrigerator, turn knob "A" to the "GAS"
position.
Turn the thermostat knob "B" one-quarter (1/4) of a turn
from the "OFF" position.
Push button "C" in until it bottoms out–and hold. When
lamp "E" stops flashing, hold push-button "C" an
additional 15 seconds. Release button "C". If the lamp
"E" starts to flash again, repeat lighting procedure. If
flame blows out, the reigniter will automatically relight
the flame.
NOTE: After changing an LP tank, or after a long
shut off period, the gas line is likely to be filled with
air. You may have to repeat the lighting procedure
several times to purge the air out of the gas lines.
A. GAS OPERATION
Refrigerators with Piezo Ignitor (RM2310 &
RM2410)
To start the refrigerator, turn knob "A" to the "GAS"
position.
Turn the thermostat knob "B" one-quarter (1/4) of a turn
from the "OFF" position.
Push button "C" in until it bottoms out–and hold. While
holding button "C", push button "D" for the piezo ignitor
several times to light the burner. This can be observed
through the flame view port, "E", on the refrigerator.
After the flame lights, continue to hold button "C" for an
additional fifteen (15) seconds. Release the button "C"
and check the flame view port "E" to make sure the
burner does not go out. If the burner goes out, repeat
the lighting procedure.
To shut off the refrigerator, turn Knob "A" to the "OFF"
position.
Refrigerators with Automatic Reigniters
(RM2510/RM2610/RM2810)
A - ON/OFF Switch
B - Thermostat, Gas/Electric
C - Safety Push-button
E - Light
Refrigerators with Piezo Ignitors (RM2310 &
RM2410)
A - ON/OFF Switch
B - Thermostat Gas/Electric
C - Safety Push-button
D - Piezo Ignitor
E - Flame View Port