SinePower Connecting the inverter
15
9.2 Connecting the inverter
!
A
I
Connect the inverter as shown:
Connecting the battery: fig. 5 and fig. 6
Connecting the ground terminal fig. 7
Connecting the 230 V power cable: fig. 8 (INPUT)
Connecting the 230 V output cable: fig. 8 (OUTPUT)
9.3 Connecting multiple appliances
The device is equipped at delivery with galvanic isolation. For the safe operation of
multiple appliances, it is essential that a circuit breaker (residual current circuit
breaker) is built into the socket distribution circuit.
Install a residual current circuit breaker in the socket distribution circuit.
9.4 Connecting the remote control (accessory)
A
Connect the remote control as shown (fig. 9).
WARNING!
Before connecting the AC output cable, make sure the inverter is
switched off at the main switch.
NOTICE!
Make sure that you do not reverse the polarity. Incorrect polarity can
damage the inverter.
NOTE
Tighten the nuts and bolts to a maximum torque of 15 Nm. Loose
connections may cause overheating.
NOTICE!
Only plug in the connection to the remote control in the remote port.
The device can be damaged by connecting it incorrectly.