- SIMPLE LEARNING:
Check if the leaves are closed, and then press F push-button for one second: DL10 LED begins flashing and the leaves begin the opening
movement.
Wait for the leaf to reach the opening stop limit and then supply an OPEN A pulse (with the radio control or with the key controlled push-button)
to stop the movement: the leaves stop and the DL10 LED stops flashing.
The procedure has ended and the gate is ready to operate. Next pulse closes leaves and they stop on automaticaly reaching closed position.
- ADVANCED COMPLETE LEARNING:
Check if the leaves are closed, and then press F push-button for more than 3 seconds: DL10 LED begins flashing and the leaf 1 begins the
opening movement. The following functions can be commanded by the OPEN A pulses (by radio control or key controlled push-button):
1° OPEN - Deceleration at opening of leaf 1
2° OPEN - Leaf 1 stops at opening and leaf 2 begins its opening movement
3° OPEN - Deceleration at opening of leaf 2
4° OPEN - Leaf 2 stops at opening and immediately begins its closing movement
5° OPEN - Deceleration at closing of leaf 2
6° OPEN - Leaf 2 stops at closing and leaf 1 begins its closing movement
7° OPEN - Deceleration at closing of leaf 1
8° OPEN - Leaf 1 stops at closing
The DL10 LED stops flashing and the gate is ready for normal operation.
Notes: •If you wish to eliminate deceleration in certain stages, wait for the leaf to reach its stop-limit and supply 2 consecutive Open pulses (by 1
second).
•If only one leaf is present, the entire sequence must nevertheless be effected. When the leaf has finished opening, supply 5 Open pulses until the
leaf begins to close, and then resume normal operation.
•It wind effected areas it is best to allow 2 second after the leaf reaches open stop befor supplying Open A to ensure full closing.
•Use of slow-down is not recommended for condominium entries.
•If, during closing / opening, the cycle stops for more consecutive times, the leaf could not reach the limit stop with slow-down. At the first
complete cycle without interruptions, the system recognizes the limit