Power Train Disassembly & Assembly
Carrier Removal from Axle
1. Place a hydraulic roller jack under the differential
carrier to support the assembly.
2. Remove all but the top two carrier to housing stud
nuts and washers.
3. Loosen the top two carrier-to-housing fasteners
and leave attached to the assembly. The fasteners
will hold the carrier in the housing.
4. Loosen the differential carrier in the axle housing.
Use a leather mallet to hit the mounting flange of
carrier at several points.
5. After the carrier is loosened, remove the top two
fasteners.
CAUTION : When using a pry bar be careful not to
damage the carrier or housing flange. Damage to
these surfaces will cause oil leaks.
6. Carefully remove the carrier from the axle housing
using the hydraulic roller jack. Use a pry bar that
has a ruound end to help remove the carrier from
the housing.
7. Lift the differential carrier by the input yoke and
place the assembly in a repair stand. Use a lifting
tool for this procedure. Do not lift by hand.