Operation Section
-82-
LP Engine
WARNING
LP fuel is flammable and can cause personal
injury.
Inspect LP fuel lines and fitting for leaks.
Inspect tank for secure mounting.
1. Turn the tank fuel valve ON by slowly turning
the valve counterclockwise. Observe the LP
gauge (if equipped).
2. Don’t press accelerator pedal, and turn the
ignition switch to the START position.
3. Once the engine starts, release the ignition
switch.
4. If the engine does not start, repeat step 2.
5. If engine coolant is cold, engine speed could be
higher than normal low idle speed. Don’t drive
forklift until engine speed becomes normal low
idle speed.
Diesel Engine
Starting a Cold Diesel Engine
Turn the key to the ON position. The start pre heat
light will come ON. The preheat light will stay ON
approximately seven seconds, depending on the
surrounding air temperature.
NOTICE
Do not engage the starter for more than 10
seconds.
When the preheat light goes OFF, turn the key to
the START position, with the accelerator pedal
pressed.
Release the key when the engine starts and
release the accelerator pedal to a low idle position.
If the engine stalls or does not start, turn the key to
the OFF position, then repeat steps 1 thru 3.
Starting a Warm Diesel Engine
Turn the key to the ON position and then to START
position, without waiting for the preheat light to go
OFF. At the same time press the accelerator.
Release the key when the engine starts and
release the accelerator pedal to a low idle position.