ES 200 EASY PLUS
—
4
4. Operation
Setting the door opening width
You can reduce the opening width of the door
(e. g. to reduce draft in the winter).
Setting the partial opening width using the program switch.
1. Close the door.
2. Turn the program switch
to the PERMANENT OPEN position.
► The door slowly opens.
3. Once the door has reached the desired partial opening
width, turn the program switch to the
PARTIAL OPEN position.
► The door will stop and save the position as the new
partial open width.
► The door closes.
Please contact the Service Department in case you are not
be able to set the partial opening width.
Shutting down the door system
1. Push the EMERGENCY STOP button.
► The door will stop immediately and can be moved by
hand
.
► The EMERGENCY STOP button remains in the
pressed-in position.
2. Turn the EMERGENCY STOP button to the right.
► The EMERGENCY STOP button will now move back
into its original position.
► The door operates again according to the set
program function.
Opening the door using the night/bank switch
The program switch is in the OFF position.
1. Push the night/bank button.
► The door unlocks and opens.
► The door closes automatically.
► The door is locked again.
Commissioning after a power outage
After a power outage, the control unit will carry out a
self-test (duration approx. 5 seconds).
The door will then slowly close and assume the previously
set program function.
Service display (optional)
The display will remind the operator that maintenance is
to be carried out on the door system. The maintenance
intervals can be set by the service technician.
You can enter a time interval (month,
e. g. every 6 months) and/or a load cycle interval
(e. g. after 80000 load cycles).
Depending on the type of event, the service display will light
up as follows:
Load cycle interval has lapsed:
► Display shows continuous light:
Time interval has lapsed:
► Display flashes (every 0.5 seconds).
Time and load cycle intervals have lapsed
► Display shows 10 seconds of continuous light and
flashes for 10 seconds.
The maintenance notification will be acknowledged by the
service technician.