3.4 Variants
Versions of the SVP/SVZ door locks are available for
various applications:
The SVP 5000 is a mechanical door lock. When the
door is closed, the door lock locks automatically. The
SVP5000 is also suitable for retrofitting doors in
which no connection cable can be laid.
The SVP4000 is an electrically monitored door
lock. When the door is closed, the door lock locks
automatically.
The SVP6000 is an electrically monitored door
lock. When the door is closed, the door lock locks
automatically. In addition, the door handle can be
electrically engaged or disengaged on the access
side. This makes the door lock suitable for doors
that occasionally need to be opened from the
outside, but are usually locked.
The SVZ6000 is an electrically monitored door
lock with the same functions as the SVP 6000,
which is used with access control components (e.g.
code card reader). Only authorized persons can
unlock the door lock from the outside or from the
inside. When the door is closed, the door lock locks
automatically. The SVZ6000 must not be used
along escape routes because it does not have an
emergency escape function.
The SVP2000 is a motorized lock whose function
can be controlled electronically. When the door
is closed, the door lock locks automatically. It
is operated separately (stand-alone, without
feedback contacts) or on an external control unit
via a DCW® bus or a CAN bus. Operation on an
electric door operator with integrated control unit
is also possible, e.g. with the ED100/ED250. The
SVP 2000 may only be used in fire and smoke
protection doors in combination with the external
Power Reserve module "SVP-PR DCW®" (item no:
70922601)!
The SVP2000F is a motorized lock with the same
functions as the SVP2000, which is also approved
for use in fire and smoke protection doors. The
SVP2000F contains an integrated Power Reserve
module. The SVP2000F cannot be switched to
"permanently open" because this function is not
permitted for use on fire and smoke protection
doors.
The SVP locks SVP 2000 and SVP 2000F are
compatible with an ED100 or ED250 from the ED
firmware version V2.200 upwards. If the EDs have
an older firmware version, this must be updated.
4
SVP/SVZ door locks
2020-03
WN 059744 45532
dormakaba Mounting instructions Product description