Doseuro Rapida 2.0 - Detailed Description of the Main Registers

Doseuro Rapida 2.0
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
XMPI0MTIRPD2ST021 16/24 Ed. 2021
S014
INPUT CONFIGURATION 4 (8.4)
N.O./N.C.
-
N.O.
S015
BEHAVIOUR IN CASE OF ERROR ON IN.3
STOP/RESTART
-
RESTART
S016
BEHAVIOUR IN CASE OF ERROR ON IN.4
STOP/RESTART
-
RESTART
S017
ERROR IN CASE OF SENSOR FAILURE
ON/OFF
-
ON
S018
PARAMETER DISPLAYED AT SWITCH-ON
1÷202
-
1
S019
MAXIMUM INVERTER MOTOR TEMPERATURE
45÷80
-
80
S020
UNIT OF MEASURE
°C,L/h or °F, gal/h
-
°C,L/h
S021
COUNTER MODE
Up/Down
-
Down
S022
ANALOGUE INPUT CONFIGURATION
4-20mA or 0-10V
-
4-20mA
S023
MAXIMUM FREQUENCY
25÷60
Hz
60
S024
ACCELERATION RAMP
0.5÷60
s
1
S025
DECELERATION RAMP
0.5÷60
s
0.35
S026
PWM MODULATION FREQUENCY
2.5-5-7.5-10-12.5-15
kHz
5
S027
MAXIMUM CURRENT (I)
1
0÷8
A
-
S028
ERROR RESET
Skip/Reset
-
Skip
S029
SERIAL NUMBER SETTING
-
-
-
S030
MOTOR VOLTAGE
110÷230
V
230
2
S031
V. CONST.
Enabled/Disabled
-
Disabled
S099
RESET TO DEFAULT VALUES
43
-
43
8.1 DETAILED DESCRIPTION OF THE MAIN REGISTERS
S001 TOTAL FLOW RATE Allows the flow rate to be changed according to the pump connected. Changing
this parameter allows the times to be displayed correctly.
S002 S003 S004 PULSE MODE Changing these parameters enables and changes the pulse mode that
can be used in the dosing mode. For more information see the chapter on operating modes.
S005 - ADJUSTMENT OF LINE Q (FLOW RATE)
SECTION 0÷10 - By modifying this parameter it
is possible to change the values of the flow rate
as a function of frequency for the range of the
Q line from 0%÷10%.
S006 - ADJUSTMENT OF LINE Q (FLOW RATE)
SECTION 10÷20 - By modifying this parameter
it is possible to change the values of the flow
rate as a function of frequency for the range of
the Q line from 11%÷20%.
S007 - ADJUSTMENT OF LINE Q (FLOW RATE)
SECTION 20÷30 - By modifying this parameter
it is possible to change the values of the flow
rate as a function of frequency for the range of
the Q line from 21%÷40%.
S008 - ADJUSTMENT OF LINE Q (FLOW RATE) SECTION 30÷40 - By modifying this parameter it is possible to
change the values of the flow rate as a function of frequency for the range of the Q line from 41%÷60%.
1
0.18-0.25kW = 3A; 0.37-0.55kW = 4A; 0.75kW = 8A
2
May vary for special motors/voltages