www.ee-co.com M70-100 Manual V2 Page 18 of 22
G.1 Electrical Troubleshoong
I. Motor does not work aer turning on the machine and pressing the
START
buon while
pulling the cung arm assembly down
Possible Causes:
1. Micro-switch placed inside the knife cover K2 is
damaged.
How to Proceed:
Check if the micro-switch is jammed. If it is jammed remove the two screws and micro- switch cover
and adjust
its
posion
so it does not
jam.
If this procedure does not yield sasfactory results, replace the
micro
-
switch.
2. Current protecon breaker inside the electrical box has been
acvated.
How to Proceed:
Press the black reset switch on the Q1 circuit
breaker.
3. The S1 contactor is
damaged.
How to Proceed:
Check with a multi-meter if the contacts operate properly. Check with
a
multi-meter if contactor coil
is
damaged..
5. EMERGENCY STOP switch, contact
K1
- (red contact) - is
damaged.
How to Proceed:
Check with a multi-meter if the contacts operate properly. If needed replace
them.
6. Power Supply is damaged or there is short-circuit in the 24VDC
circuit.
How to Proceed:
Check if there is 24VDC at power supply output and if the green diode is
illuminated.
If the diode is not illuminated, check if 120 VAC is at the power supply input. If it is present, the
power supply is damaged.
If
the green LED is blinking, the 24VDC circuit has an electrical short
present. Trace the short and repair